0800 228 9574

For all our services call us

GAS BOILER ERROR CODES

The Meaning of Vaillant Boiler Error Codes

Troubleshooting Your Combi Boiler

DIAGNOSE BOILER PROBLEMS

What are Vaillant Boiler Error Codes for?

When it comes to gas boilers, the family-owned German-based company Vaillant are market leaders, producing a range of combination, regular and system gas boilers for heating and supplying hot water that are popular in Britain.

However good a boiler may be however, they are not invincible and boiler breakdown is always an unpleasant threat that looms if your boiler develops a fault.

Vaillant have made it easier to diagnose the problem with your gas boiler by providing its appliances with built-in error codes (or fault codes) to alert you to specific issues. Each error code indicates what the fault is, so it’s wise to make sure you know what the codes mean.

Most gas boiler faults can only be rectified by a qualified gas-safe registered engineer, so although you can use these Vaillant boiler error codes as a guide, its best to call in a professional to attend to your faulty Vaillant boiler.

Prestige Services provide first class gas boiler repairs across the Cotswolds, North Wiltshire and West Oxfordshire – so if you see an error code on your boiler’s display panel get in touch.

We’ve put together this handy guide to help you identify what some of the most commonly seen Vaillant Combi gas boiler codes mean on the latest Vaillant Combi boiler models.

POPULAR BOILER MODEL

Vaillant ecoTec Pro combi boiler error codes

Flow temperature sensor faulty or not connected

Return temperature sensor faulty or not connected

Flow temperature sensor faulty or has short-circuited

Return temperature sensor faulty or has short-circuited

Maximum temperature at the flow/return temperature sensor is too high when the safety cut out function is operating using the Negative Temperature Coefficient (NTC)

No/insufficient water because the water pressure is too low

Temperature spread is too great and/or water circulation too low

Safety switch-off: Temperature increase too fast

Safety switch-off: Flue gas temperature too high

Gas valve assembly stepper motor faulty or not connected

Safety switch-off: Monitoring electrode reports an incorrect flame

Failure during start-up or ignition unsuccessful. Gas pressure monitor or thermal cut-out has been triggered

Gas supply interrupted intermittently. Re-ignition failed

Fan faulty or not connected

Undervoltage on the eBUS (Vaillant communication system)

The gas valve assembly cannot be actuated

Delayed switch-off sequence for the gas valve after the flame is extinguished

EEPROM (Electronic controls in the system) are faulty

Electronics, safety-relevant sensor or cable faulty

Electronics faulty or too hot due to external influences

Implausible flame signal

Flame monitor reports an unstable flame signal

Incorrect/missing Device Specific Number or incorrect/missing coding resistor

Flow temperature sensor returns implausible values

Temperature difference between flow and return temperature sensor is too great

Water pressure sensor reports that the water pressure is too low

Water pressure too high

Insufficient pressure jump detected when starting the pump

No flue non-return flap feedback; condensate pump over flow

UK link box is connected without the domestic hot water temperature sensor being bridged

Temperature difference between flow and return temperature sensor is too small

Temperature difference is implausible

Flow/return temperature sensors returning incorrect/implausible values

POPULAR BOILER MODEL

Vaillant ecoTec Plus combi boiler error codes

Flow temperature sensor defective or not connected

Return temperature sensor faulty or not connected

Cylinder temperature sensor for the shift-load cylinder defective or not connected

Temperature sensor for the shift-load cylinder defective or not connected

Flow temperature sensor defective or has short-circuited

Return temperature sensor faulty or has short-circuited

Cylinder temperature sensor defective or has short-circuited

Short circuit in the Cylinder sensor. The Warm start sensor/cylinder temperature sensor is defective or not connected

Maximum temperature at the flow/return temperature sensor is too high when the safety cut- out function is operating using the NTC (negative temperature coefficient)

Safety cut out because there is no/insufficient water in the product or the water pressure is too low

Safety switch-off due to the temperature spread being too great or water circulation too low

Safety switch-off because temperature increase is too fast

Safety switch-off because the flue gas temperature too high

Gas valve assembly stepper motor defective or not connected

Safety switch-off because the monitoring electrode reports an incorrect flame

Failure during start-up or ignition unsuccessful. Gas pressure monitor or thermal cut-out has been triggered

Gas supply interrupted intermittently. Reignition failed

Fan defective or not connected

Coding resistor or gas group resistor has caused a short circuit

Undervoltage on the eBUS

Mass flow sensor defective or not connected

Mass flow sensor faulty 22

No gas inlet pressure or insufficient gas inlet pressure causes faults when the appliance is started

All-gas sensor defective or has short-circuited

Safety shutdown after the CO limit value is exceeded

Regulation fault caused by corroded ignition electrode

The gas valve assembly cannot be actuated

Delayed switch-off sequence for the gas valve after the flame is extinguished

EEPROM faulty

Electronics, safety-relevant sensor or cable is defective

Electronics defective or overheated due to external influences

Implausible flame signal

Flame monitor reports an unstable flame signal

Incorrect/missing Device Specific Number or incorrect/missing coding resistor

Flow temperature sensor returns implausible values

Temperature difference between flow and return temperature sensor is too great

Water pressure sensor reports that the water pressure is too low

Water pressure too high

Insufficient pressure jump detected when starting the pump

No flue non-return flap feedback; condensate pump over flow

UK link box is connected without the domestic hot water temperature sensor being bridged

Inlet temperature sensor faulty or not connected

Cylinder is not fully charged after specified time

External current anode defective or not connected

Temperature difference between flow and return temperature sensor is too small

Temperature difference is implausible

Flow/return temperature sensors returning incorrect/implausible values

Communication fault with actoSTOR interrupted

Sensor on the actoSTOR is defective

Combustion quality outside the permitted range

Sensors return implausible values

POPULAR BOILER MODEL

Vaillant ecoFit Pure combi boiler error codes

Flow temperature sensor defective or not connected

Return temperature sensor faulty or not connected

Flow temperature sensor defective or has short-circuited

Return temperature sensor faulty or has short-circuited

Cylinder temperature sensor defective or has short-circuited

Short circuit in the Cylinder sensor. The Warm start sensor/cylinder temperature sensor is defective or not connected

Maximum temperature at the flow/return temperature sensor is too high when the safety cut- out function is operating using the NTC (negative temperature coefficient)

Safety cut out because there is no/insufficient water in the product or the water pressure is too low

Safety switch-off due to the temperature spread being too great or water circulation too low

Safety switch-off because temperature increase is too fast

Safety switch-off because the flue gas temperature too high

Safety switch-off because the monitoring electrode reports an incorrect flame

Failure during start-up or ignition unsuccessful. Gas pressure monitor or thermal cut-out has been triggered

Fan defective or not connected

Undervoltage on the eBUS

The gas valve assembly cannot be actuated

Delayed switch-off sequence for the gas valve after the flame is extinguished

Electronics, safety-relevant sensor or cable is defective

Electronics defective or overheated due to external influences

Implausible flame signal

Flame monitor reports an unstable flame signal

Incorrect/missing Device Specific Number or incorrect/missing coding resistor

Flow temperature sensor returns implausible values

Temperature difference between flow and return temperature sensor is too great

Water pressure sensor reports that the water pressure is too low

Water pressure too high

Insufficient pressure jump detected when starting the pump

No flue non-return flap feedback; condensate pump over flow

Fault: Condensate or smoke

UK link box is connected without the domestic hot water temperature sensor being bridged

Temperature difference between flow and return temperature sensor is too small

Temperature difference is implausible

Flow/return temperature sensors returning incorrect/implausible values

Fault: Underfloor heating contact

Fault: Electrodes

Fault: Gas valve

Fault: Pump

POPULAR BOILER MODEL

Vaillant ecoTec Exclusive Green iQ combi boiler error codes

Flow temperature sensor defective or not connected

Return temperature sensor faulty or not connected

Cylinder temperature sensor for the shift-load cylinder defective or not connected

Temperature sensor for the shift-load cylinder defective or not connected

Flow temperature sensor defective or has short-circuited

Return temperature sensor faulty or has short-circuited

Cylinder temperature sensor defective or has short-circuited

Short circuit in the Cylinder sensor. The Warm start sensor/cylinder temperature sensor is defective or not connected

Maximum temperature at the flow/return temperature sensor is too high when the safety cut- out function is operating using the NTC (negative temperature coefficient)

Safety cut out because there is no/insufficient water in the product or the water pressure is too low

Safety switch-off due to the temperature spread being too great or water circulation too low

Safety switch-off because temperature increase is too fast

Safety switch-off because the flue gas temperature too high

Gas valve assembly stepper motor defective or not connected

Safety switch-off because the monitoring electrode reports an incorrect flame

Failure during start-up or ignition unsuccessful. Gas pressure monitor or thermal cut-out has been triggered

Gas supply interrupted intermittently. Reignition failed

Fan defective or not connected

Pressure switch

Fault: Air/flue gas duct

Coding resistor or gas group resistor has caused a short circuit

Undervoltage on the eBUS

All-gas sensor defective or has short-circuited

Safety shutdown after the CO limit value is exceeded

Regulation fault caused by corroded ignition electrode

The gas valve assembly cannot be actuated

Delayed switch-off sequence for the gas valve after the flame is extinguished

EEPROM faulty

Electronics, safety-relevant sensor or cable is defective

Electronics defective or overheated due to external influences

Implausible flame signal

Flame monitor reports an unstable flame signal

Incorrect/missing Device Specific Number or incorrect/missing coding resistor

Flow temperature sensor returns implausible values

Temperature difference between flow and return temperature sensor is too great

Water pressure sensor reports that the water pressure is too low

Water pressure too high

Insufficient pressure jump detected when starting the pump

No flue non-return flap feedback; condensate pump over flow

Inlet temperature sensor faulty or not connected

Cylinder is not fully charged after specified time

External current anode defective or not connected

Temperature difference between flow and return temperature sensor is too small

Temperature difference is implausible

Flow/return temperature sensors returning incorrect/implausible values

Communication fault with actoSTOR interrupted

Sensors return implausible values

MAINTAIN YOUR BOILER

Other Vaillant Boiler models

If you have any other type, make or model of Vaillant boiler which is not working properly and/or displaying an error code, feel free to contact us at Prestige Services for advice and assistance. We cover a wide range of locations in southern England.

A message from Leisa

I hope you find our web site useful, should you have any questions please feel free to call me on:

0800 228 9574

Get in Touch